Low-pressure compressor: Compression ratio down to 1.1, saves 17% energy in transitional seasons
Dual expansion valves: 7% low-load dehumidification, prevents condensation
Wet membrane humidifier: Easy upkeep, saves 95%+ energy
Smart mode switching: Uses outdoor air for free cooling
Indoor Unit Model | CTACJ-CRF3060 |
Main Power Supply | 380V 3Ph + 50Hz |
Air Outlet Mode | Front Air Supply |
Cooling Capacity (kW) | 60 |
Sensible Cooling Capacity (kW) | 60 |
Maximum Current of Unit (FLA) (A) | 57.2 |
Number of Compressors | 1 |
Indoor Fan Performance Parameters - Number of Fans | 3 |
Heating Performance Parameters - Heating Capacity (kW) | 9 |
Humidifier Performance Parameters - Humidification Capacity (kg/h) | 4.5 |
Connection Pipe Size Specification (30m) - Liquid Pipe (mm) | 16 |
Connection Pipe Size Specification (30m) - Gas Pipe (mm) | 22 |
Humidifier Inlet Pipe (External Thread) | G1/2" |
Unit Natural Drain Pipe (mm) | ID16*OD24 |
Unit Water Pump Drain Pipe (mm) | ID12*OD16 |
Unit Dimensions and Weight - Unit Width × Depth × Height (mm) | 600×1200×2000 (2200) |
Unit Dimensions and Weight - Weight (kg) | 310 |
Outdoor Unit Performance Parameters (40ºC) - Flat Panel Outdoor Unit Model | CMT088SP |
Outdoor Unit Performance Parameters (45ºC) - Centralized Outdoor Unit Model | CMT099FP |
Recommended Air Switch and Cable Specifications - Recommended Air Switch (A) | 63 |
Recommended Air Switch and Cable Specifications - Indoor Unit Cable Wire Diameter (mm²) | 4×16 + 1×16 |
Remarks 1. Standard working conditions: Indoor return air temperature 37ºC, relative humidity 24%, air - cooled outdoor ambient temperature 35ºC, ESP = 10Pa; 2. The indoor unit can be optionally single - cooling + electric heating / constant temperature and humidity. The maximum working current and recommended air switch are configured according to the constant temperature and humidity unit; 3. The above table is only for some parameters. The specific configuration is subject to the actual purchase nameplate. For more parameter information, please contact Hisense Company. |
Outdoor Unit Model | Number of Fans | Single/Dual System | Gas Pipe (mm) | Liquid Pipe (mm) | Power Line Specification (mm) | Net Unit Weight (kg) | Overall Dimensions (mm) | ||
L | W | H | |||||||
CMT038SP | 1 | Single System | 22 | 15.88 | 4*1.5 + 1*1.5 | 124 | 1146 | 817 | 1048 |
CMT044SP | 1 | Single System | 22 | 15.88 | 4*1.5 + 1*1.6 | 134 | 1146 | 817 | 1216 |
CMT050SP | 1 | Single System | 22 | 15.88 | 4*1.5 + 1*1.7 | 145 | 1146 | 817 | 1216 |
CMT055SP | 1 | Single System | 22 | 15.88 | 4*1.5 + 1*1.8 | 152 | 1346 | 817 | 1216 |
CMT066SP | 2 | Single System | 22 | 15.88 | 4*1.5 + 1*1.9 | 168 | 2171 | 817 | 1048 |
CMT072SP | 2 | Single System | 22 | 15.88 | 4*1.5 + 1*1.10 | 172 | 2171 | 817 | 1048 |
CMT088SP | 2 | Single System | 22 | 15.88 | 4*1.5 + 1*1.11 | 245 | 2171 | 817 | 1216 |
CMT099SP | 2 | Single System | 22 | 15.88 | 4*1.5 + 1*1.12 | 245 | 2171 | 817 | 1216 |
Outdoor Unit Model | Number of Fans | Single/Dual System | Gas Pipe (mm) | Liquid Pipe (mm) | Power Line Specification (mm²) | Net Unit Weight (kg) - Fluorine Pump | Overall Dimensions (mm) | ||
L | W | H | |||||||
CMT044FP | 1 | Single System | 22 | 19.05 | 4×1.5 + 1×1.5 | 205 | 1275 | 1100 | 1985/130/2205 |
CMT050FP | 1 | Single System | 22 | 19.05 | 4×1.5 + 1×1.5 | 205 | 1275 | 1100 | 1985/130/2205 |
CMT066FP | 1 | Single System | 22 | 19.05 | 4×1.5 + 1×1.5 | 235 | 1275 | 1100 | 1985/2130/2205 |
CMT088FP | 1 | Single System | 22 | 19.05 | 4×1.5 + 1×1.5 | 265 | 1275 | 1100 | 1985/2130/2205 |
CMT099FP | 1 | Single System | 22 | 19.05 | 4×1.5 + 1×1.5 | 265 | 1275 | 1100 | 1985/2130/2205 |
How does a data center achieve precise temperature and humidity control?
Through advanced sensing technology and control systems, temperature accuracy of ±0.5°C and humidity control of ±3% RH can be achieved, ensuring optimal operating conditions for data center equipment.
What energy efficiency and saving measures are included?
Utilizes high-efficiency components such as variable frequency compressors and EC fans, combined with intelligent control systems that automatically adjust output based on actual load, effectively reducing energy consumption.
How is reliability and redundancy designed?
Redundant design and fault warning systems are typically implemented to enhance overall system reliability and availability.
How does it adapt to different environmental conditions?
The design considers the year-round cooling needs of data centers, even during winter. Equipment, pipelines, and valves are equipped with effective measures to prevent freezing or cold air from directly entering the main server room, which could lead to condensation and negatively impact electronic information equipment.
What are the maintenance and operational costs?
The design is simple and easy to maintain, while energy-saving technologies reduce operational costs. For instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.
How does it address high heat density issues?
For high-density IT cabinets, high heat density solutions are provided to effectively address localized hotspots, including regional high heat density strategies and localized hotspot mitigation methods. For instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.