Product Model | CTACJ-CMF3040 |
Cooling Capacity (kW) | 40.1 |
Sensible Cooling Capacity (kW) | 36.1 |
System Type | Single System |
Refrigerant Type | R410A |
Heating Method | PTC Electric Heating |
Heating Capacity (kW) | 9 |
Humidification Method | Wet Film Humidification |
Humidification Capacity (kg/h) | 6 |
Indoor Unit Parameters | |
Indoor Unit, Width (mm) | 930 |
Indoor Unit, Depth (mm) | 996 |
Indoor Unit, Height (mm) | 1995 |
Centralized Outdoor Unit Parameters | |
Outdoor Unit, Width (mm) | 1280 |
Outdoor Unit, Depth (mm) | 1100 |
Outdoor Unit, Height (mm) | 2128 |
Operating Conditions:Indoor return air dry - bulb temperature 24°C, wet - bulb temperature 17°C, outdoor dry - bulb temperature 35°C |
How does a data center achieve precise temperature and humidity control?
Through advanced sensing technology and control systems, temperature accuracy of ±0.5°C and humidity control of ±3% RH can be achieved, ensuring optimal operating conditions for data center equipment.
What energy efficiency and saving measures are included?
Utilizes high-efficiency components such as variable frequency compressors and EC fans, combined with intelligent control systems that automatically adjust output based on actual load, effectively reducing energy consumption.
How is reliability and redundancy designed?
Redundant design and fault warning systems are typically implemented to enhance overall system reliability and availability.
How does it adapt to different environmental conditions?
The design considers the year-round cooling needs of data centers, even during winter. Equipment, pipelines, and valves are equipped with effective measures to prevent freezing or cold air from directly entering the main server room, which could lead to condensation and negatively impact electronic information equipment.
What are the maintenance and operational costs?
The design is simple and easy to maintain, while energy-saving technologies reduce operational costs. For instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.
How does it address high heat density issues?
For high-density IT cabinets, high heat density solutions are provided to effectively address localized hotspots, including regional high heat density strategies and localized hotspot mitigation methods. For instance, centralized systems have higher maintenance costs, whereas decentralized systems require less than 1 million RMB in annual operating expenses.